Detail NR1 ELEC/INST RM/KL/CM
2026-07-21
363-FN1-&-363-FN2-&-L1C-TL1
Wahyu Adi Triono
Problem: Greasing motor noise 2.6 gE-2.9 gE. Vibrator not tight
Action:
Check actual noise with CBM team Mr. Najib found 363 FN2 for LS and FS below 2 gE but 363 FN1 for FS noise 2.5 gE add grease 15 times measure noise result 0.85 gE and for LS noise below 1 gE. Check noise at 363 MD1 for FS below 1 gE but LS 2.4 gE add grease 15 times measure noise 1.5 gE Check at location found support vibrator broken at round bar. Repare round bar by mechanic team result function vibrator normal ( EDI & ADI & DADANG & CBM NAJIB )

Status: done